Here are possible solutions to try when the garage door opener hums and the door does not move.
The following garage door openers will have different resolutions:
| WARNING |
|---|
To prevent possible SERIOUS INJURY or DEATH:
|
| Brief Hum | The Springs May Be Broken | Contact a trained door technician |
|---|---|---|
| Brief Hum | The Door Lock May Be Activated | Disable the door lock |
| Brief Hum | The Trolley May Be Stuck on the Stop Bolt or Stop Tab | See How To Get The Trolley Off The Stop Bolt Or Stop Tab |
| Hums for About 30 Seconds | The door may not be connected to the garage door opener | Depending on your opener, you may see only the trolley move along the rail when you activate the opener. Ensure the door is connected to the garage door opener. Use the emergency release handle to reconnect the door. See How To Disconnect The Garage Door Opener To Manually Open Or Close The Garage Door. |
| Brief Hum | Springs May Be Broken | Contact a trained door technician |
|---|---|---|
| Brief Hum | Door Lock May Be Activated | Disable the door lock |
| Hums For About 30 Seconds | The Door May Not Be Connected to the Garage Door Opener | You may see the rack along the inside of the rail of the opener. Ensure the door is connected to the garage door opener. Use the emergency release handle to reconnect the door. See How To Disconnect The Garage Door Opener To Manually Open Or Close The Garage Door. |
| Hums Longer Than 5 Seconds | The rack may be stripped | Check the rack, a black piece that runs up and down the inside of the rail. If it is worn, replace it. |
| Brief Hum | Possible Capacitor Issue | Disconnect ALL power. Remove the opener cover and inspect the capacitor for oil or swelling. Replace the capacitor. |
| Hums After Capacitor Has Been Replaced | The motor is damaged | Replace the motor |
| Hums Until Unplugged | The receiver logic board is damaged | Replace the logic board |
| Hums For 1 to 2 Seconds | The Door May Be Disengaged | Pull on the red emergency handle, manually disengage the door lock, then try opening door manually |
|---|---|---|
| Hums for more than 2 seconds | The Collar May Be Slipping on the Torsion Bar | Tighten all screws on the collar, then try operating the door again |

Strictly necessary cookies are vital for our website’s core functions, such as security, network management, and accessibility. Since they are essential, these cookies cannot be disabled in our systems.
Third party trackers collect information to use for analytics and to personalize your experience with targeted ads. Under the Colorado CPA, the Virginia CDPA, the Texas DPSA, the Oregon CPA, the Montana CDPA, and the Florida DBR, you have the right to opt-out of the sale of your personal data to third parties, of targeted advertising related processing, and of some types of profiling. You may exercise your rights by using the toggles below. If you opt out, the ads and content that you see may not be as relevant to you. Under the Colorado CPA, you have the right to opt back in to these categories at any time should you initially choose to opt out, and you may do so using the same toggles provided below. For more details on the data we process and how to exercise your rights, and to view information related to required opt-in disclosures, see our Privacy Policy
We and our advertising partners may set these cookies to deliver relevant ads both on our site and across other sites. You can opt-out of these cookies, but you may see less personalized advertising as a result.
These cookies, along with select third-party partners, help us understand how visitors use our site, such as which pages are popular and how long they stay. You can opt-out of these cookies, but your experience may be less customized.